Print This Email This

NOTE: All documents linked from this page are in  PDF-format.

Interpretation 62.1-2004-01 (refers to the requirements presented in ANSI/ASHRAE Standard 62.1-2004, Section 6.2.6.2 Short-Term Conditions, specifically the interruption of ventilation air.)

Interpretation 62.1-2004-2 (refers to the requirements presented in ANSI/ASHRAE Standard 62.1-2004, Table 6-1 Minimum Ventilation Rates in Breathing Zone, specifically for the Occupancy Category: Swimming (pool and deck).)

Interpretation 62.1-2004-3 (refers to the requirements presented in ANSI/ASHRAE Standard 62.1-2004, Table 6-1, Minimum Ventilation Rates in Breathing Zone, relating to Swimming (pool and deck))

Interpretation 62.1-2004-4 (refers to the requirements presented in ANSI/ASHRAE Standard 62.1-2004, Table 6-1, Minimum Ventilation Rates in Breathing Zone, relating to General: Corridors)

Interpretation 62.1-2004-5 (refers to the requirements presented in ANSI/ASHRAE Standard 62.1-2004, Section 6.3.1.1 Contaminant Sources)

Interpretation 62.1-2004-6 (refers to the requirements presented in ANSI/ASHRAE Standard 62.1-2004, Sections 6.2.2 Zone Calculations, 6.2.6.2 Short-Term Conditions, and 6.2.7 Dynamic Reset.)

Interpretation 62.1-2004-7 (refers to the requirements presented in ANSI/ASHRAE Standard 62.1-2004, Table 6-1, General Note 7, and Table E-3 relating to vehicles.)

Interpretation 62.1-2004-8 (refers to the requirements presented in ANSI/ASHRAE Standard 62.1-2004, Table 6-1, Minimum Ventilation Rates in Breathing Zone, relating to an Office Building.)

Interpretation 62.1-2004-9 (refers to the requirements presented in ANSI/ASHRAE Standard 62.1-2004, Section 6.2.2 Zone Calculations and Table 6-1 Minimum Ventilation Rates in Breathing Zone, relating to Retail spaces.)

Interpretation 62.1-2004-10 (refers to the requirements presented in ANSI/ASHRAE Standard 62.1-2004, Table 6-1 Minimum Ventilation Rates in Breathing Zone, relating to indoor contaminant levels.)

Interpretation 62.1-2004-11 (refers to the requirements presented in ANSI/ASHRAE Standard 62.1-2004, Table 6-1 and Section 6.2.9, relating to smoking areas and ETS.)

Interpretation 62.1-2004-12 (refers to the requirements presented in ANSI/ASHRAE Standard 62.1-2004, Section 6.3 Indoor Air Quality Procedure, relating to ETS.)

Interpretation 62.1-2004-13 (refers to the requirements presented in ANSI/ASHRAE Standard 62.1-2004, Section 6.2 Ventilation Rate Procedures, specifically Sections 6.2.2.1, 6.2.5.3, and 6.2.6.2 relating to the calculation of system average population.)

Interpretation 62.1-2004-14 (refers to the requirements presented in ANSI/ASHRAE Standard 62.1-2004, Table 6-1 Minimum Ventilation Rates in Breathings Zone – dormitories, patient rooms and pet shops, and Sections 6.2 and 8.1.3 relating to buildings alterations or change-of-use dealing with pets.)

Interpretation 62.1-2004-15 (refers to the requirements presented in ANSI/ASHRAE Standard 62.1-2004, Section 6.2 Ventilation Rate Procedure, specifically Section 6.2.5.2 and Appendix A and the VRP Excel Spreadsheet.)

 